Zobrazeno 1 - 10
of 57
pro vyhledávání: '"Agnieszka Syntfeld-Kazuch"'
Autor:
Marcin Bielewicz, Aleksandr Bancer, Andrzej Dziedzic, Jaroslaw Grzyb, Elzbieta Jaworska, Grzegorz Kasprowicz, Michal Kiecana, Piotr Kolasinski, Michal Kuc, Michal Kuklewski, Marcin Pietrzak, Krzysztof Pozniak, Maciej Sitek, Mikolaj Sowinski, Łukasz Świderski, Agnieszka Syntfeld-Kazuch, Jaroslaw Szewinski, Wojciech Marek Zabołotny
Publikováno v:
Electronics; Volume 12; Issue 6; Pages: 1492
A Modular COsmic Ray Detector (MCORD) was prepared for use in various physics experiments. MCORD detectors can be used in laboratory measurements or can become a part of large measurement sets. MCORD can be used as a muon detector, a veto system, or
Autor:
Kamil Brylew, S. Gridin, S. Vasyukov, Alberto Gola, W. Czarnacki, Z. Mianowska, A. Gektin, Claudio Piemonte, X. Lu, T. Zawistowski, Lukasz Swiderski, Marek Moszynski, Tomasz Szczesniak, M. Grodzicka-Kobylka, M. R. Mayhugh, T. Sworobowicz, Wlodzimierz Klamra, Alessandro Ferri, Fabio Acerbi, Agnieszka Syntfeld-Kazuch, Richard T. Williams
Publikováno v:
Nuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment. 916:32-36
A custom design cryostat was constructed to study the temperature dependence of relative light yield and non-proportionality trends of scintillators between −182 °C and +152 °C. CsI:Tl crystal response to γ -rays and X-rays was investigated be
Autor:
Marek Moszynski, X. Lu, M. R. Mayhugh, S. Vasyukov, S. Gridin, Richard T. Williams, Lukasz Swiderski, Z. Mianowska, S. Mianowski, Tomasz Szczesniak, Andrzej Dziedzic, P. Sibczynski, A. Gektin, Agnieszka Syntfeld-Kazuch
Publikováno v:
Nuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment. 914:165-172
The light response of cesium iodide crystals was measured at temperatures of 303 K (30 °C) to 203 K ( − 70 °C) and for gamma sources with energies from 17 keV to 835 keV. Two different methods were used to determine the properties of the CsI:Tl c
Autor:
Agnieszka Syntfeld-Kazuch, Richard T. Williams, A. Gektin, Marek Moszynski, P. Sibczynski, M. Grodzicka, P. Schotanus, Tomasz Szczesniak, N.V. Shiran, Lukasz Swiderski
Publikováno v:
IEEE Transactions on Nuclear Science. 63:459-466
According to the present knowledge, the non-proportionality of the light yield of scintillators appears to be the fundamental limitation of energy resolution. However, several observations collected in the last 15 years on the influence of slow compo
Autor:
T. Szczęśniak, Agnieszka Syntfeld-Kazuch, Lukasz Swiderski, Marek Moszynski, J. Iwanowska, M. Grodzicka, P. Sibczynski
Publikováno v:
Nuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment. 805:25-35
According to current knowledge, the non-proportionality of the light yield of scintillators appears to be a fundamental limitation of energy resolution. A good energy resolution is of great importance for most applications of scintillation detectors.
Autor:
Amélie Grabowski, D. Wolski, P. Sibczynski, Adrien Sari, Joanna Iwanowska-Hanke, K. Grodzicki, Felix Pino, Lukasz Swiderski, Marek Moszynski, C.L. Fontana, Carlo Tintori, Agnieszka Syntfeld-Kazuch, Alessandro Iovene, Frederic Laine, Matthieu Hamel, Andrzej Dziedzic, Frederick Carrel
Publikováno v:
EPJ Web of Conferences
EPJ Web of Conferences, 2018, 170, pp.07012. ⟨10.1051/epjconf/201817007012⟩
EPJ Web of Conferences, Vol 170, p 07012 (2018)
ANIMMA 2017 – Advancements in Nuclear Instrumentation Measurement Methods and their Applications
ANIMMA 2017 – Advancements in Nuclear Instrumentation Measurement Methods and their Applications, Jun 2017, Liège, Belgium. pp.07012, ⟨10.1051/epjconf/201817007012⟩
EPJ Web of Conferences, 2018, 170, pp.07012. ⟨10.1051/epjconf/201817007012⟩
EPJ Web of Conferences, Vol 170, p 07012 (2018)
ANIMMA 2017 – Advancements in Nuclear Instrumentation Measurement Methods and their Applications
ANIMMA 2017 – Advancements in Nuclear Instrumentation Measurement Methods and their Applications, Jun 2017, Liège, Belgium. pp.07012, ⟨10.1051/epjconf/201817007012⟩
In this paper we present the prompt photofission neutron detection performance of undoped CaF2 scintillator using Threshold Activation Detection (TAD). The study is carried out in the frame of C-BORD Horizon 2020 project, during which an efficient to
Externí odkaz:
https://explore.openaire.eu/search/publication?articleId=doi_dedup___::ce8789399fb45cae38b785b6873edb51
http://hdl.handle.net/11577/3287663
http://hdl.handle.net/11577/3287663
Autor:
S. Moretto, Wojciech Gesikowski, Marek Szawlowski, Frederic Laine, Cedric Carasco, Andrzej Dziedzic, Cristiano Fontana, Joanna Iwanowska-Hanke, Frederick Carrel, Felix Pino, Agnieszka Syntfeld-Kazuch, K. Grodzicki, Jerzy Godlewski, Marek Moszynski, Guillaume Sannie, D. Wolski, Lukasz Swiderski, P. Sibczynski, Aleksandra Dolebska, Bertrand Perot, Z. Mianowska, Adrien Sari, A. Sardet, Amélie Grabowski
Publikováno v:
IEEE Xplore
2017 IEEE Nuclear Science Symposium and Medical Imaging Conference (NSS/MIC)
2017 IEEE Nuclear Science Symposium and Medical Imaging Conference (NSS/MIC), Oct 2017, Atlanta, United States. pp.1-3, ⟨10.1109/NSSMIC.2017.8532735⟩
2017 IEEE Nuclear Science Symposium and Medical Imaging Conference (NSS/MIC)
2017 IEEE Nuclear Science Symposium and Medical Imaging Conference (NSS/MIC), Oct 2017, Atlanta, United States. pp.1-3, ⟨10.1109/NSSMIC.2017.8532735⟩
International audience; In the frame of the C-BORD project, five innovate technology pillars for Non-Intrusive Inspection (NII) are under development. Freight containers are potential means for smuggling, drug trafficking and transport of dangerous o
Externí odkaz:
https://explore.openaire.eu/search/publication?articleId=doi_dedup___::80d4eaa26f8c8d2da3f92b21eecdd6a3
https://hal.science/hal-01990519
https://hal.science/hal-01990519
Autor:
M. R. Mayhugh, Claudio Piemonte, S. Vasyukov, W. Czarnacki, S. Gridin, Marek Moszynski, Fabio Acerbi, Agnieszka Syntfeld-Kazuch, M. Grodzicka-Kobylka, Wlodzimierz Klamra, Tomasz Szczesniak, Lukasz Swiderski, Richard T. Williams, T. Sworobowicz, Alberto Gola, Z. Mianowska, X. Lu, A. Gektin
Publikováno v:
2017 IEEE Nuclear Science Symposium and Medical Imaging Conference (NSS/MIC).
A custom designed cryostat was constructed to measure the response of a CsI:Tl scintillator in temperature range from $- 183 ^{circ}\mathrm {C}$ up to $+90 ^{circ}\mathrm {C}$. The light readout was realized using a SiPM developed by FBK in near ultr
Autor:
Agnieszka Syntfeld-Kazuch, Marek Moszynski, Tomasz Szczesniak, Lukasz Swiderski, Marek Szawlowski
Publikováno v:
Nuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment. 749:68-73
This study presents a simple experimental setup for precise inspection of scintillation decay character-istics as a function of the energy deposited in scintillators. The results are discussed for NaI:Tl, LSO:Ceand CeBr 3 crystals. The tested samples
Autor:
Marek Moszynski, Amélie Grabowski, Alessandro Iovene, Michal Matusiak, Lukasz Swiderski, Adrien Sari, J. Iwanowska, Frederick Carrel, Frederic Laine, Tymoteusz Kosinski, D. Wolski, Agnieszka Syntfeld-Kazuch, P. Sibczynski, Matthieu Hamel, Andrzej Dziedzic, Carlo Tintori, K. Grodzicki
Publikováno v:
2016 IEEE Nuclear Science Symposium, Medical Imaging Conference and Room-Temperature Semiconductor Detector Workshop (NSS/MIC/RTSD)
2016 IEEE Nuclear Science Symposium, Medical Imaging Conference and Room-Temperature Semiconductor Detector Workshop (NSS/MIC/RTSD), Oct 2016, Strasbourg, France. pp.8069697, ⟨10.1109/NSSMIC.2016.8069697⟩
2016 IEEE Nuclear Science Symposium, Medical Imaging Conference and Room-Temperature Semiconductor Detector Workshop (NSS/MIC/RTSD), Oct 2016, Strasbourg, France. Institute of Electrical and Electronics Engineers Inc., 2017-January, 2017, 〈10.1109/NSSMIC.2016.8069697〉
2016 IEEE Nuclear Science Symposium, Medical Imaging Conference and Room-Temperature Semiconductor Detector Workshop (NSS/MIC/RTSD), Oct 2016, Strasbourg, France. pp.8069697, ⟨10.1109/NSSMIC.2016.8069697⟩
2016 IEEE Nuclear Science Symposium, Medical Imaging Conference and Room-Temperature Semiconductor Detector Workshop (NSS/MIC/RTSD), Oct 2016, Strasbourg, France. Institute of Electrical and Electronics Engineers Inc., 2017-January, 2017, 〈10.1109/NSSMIC.2016.8069697〉
Conference of 2016 IEEE Nuclear Science Symposium, Medical Imaging Conference and Room-Temperature Semiconductor Detector Workshop, NSS/MIC/RTSD 2016 ; Conference Date: 29 October 2016 Through 6 November 2016; Conference Code:131365; International au
Externí odkaz:
https://explore.openaire.eu/search/publication?articleId=doi_dedup___::5bdfe1d3886c6a54379385b45cd90864
https://cea.hal.science/cea-01809224/document
https://cea.hal.science/cea-01809224/document