Chloride-induced corrosion is one of the most important causes of the strength degradation of reinforced concrete (RC) bridges. As the piers of RC bridges are important elements for sustaining lateral loads, corrosion of pier columns may lead to sign
Publikováno v:
Bulletin of Earthquake Engineering. 20:5905-5942
One of the main components for the development of regional seismic risk models is the fragility functions for common building types. Due to the differences between the national design codes, construction practices, and construction materials, it is n
Autor:
Amir Reza Taherian, Afshin Kalantari
Publikováno v:
Bulletin of Earthquake Engineering. 19:1289-1309
Modern seismic codes employed the uniform hazard basis for seismic design, which defines design ground motion with a fixed return period for different sites. Seismic design for uniform hazard ground motion does not lead to the goal of uniform structu
Autor:
Amir Reza Taherian, Afshin Kalantari
Publikováno v:
Journal of Seismology. 23:1299-1311
Iran is located in a very high seismic zone. The current national code of design of buildings referred to as Standard No. 2800 (STD-2800) employs the design-basis earthquake (DBE) based on the uniform hazard philosophy. New generations of seismic cod
Publikováno v:
Iranian Journal of Science and Technology, Transactions of Civil Engineering. 45:1197-1210
In this study, the effects of the vertical ground motion component (VGMC) of near-fault records on the structure as well as sliding-rubber bearings have been investigated. For this purpose, a highway bridge with sliding-rubber hybrid isolators was mo
Autor:
Afshin Kalantari, Reihane Shafie Panah
Publikováno v:
KSCE Journal of Civil Engineering. 23:1662-1669
Negative stiffness has shown a capable characteristic in reduction of seismic response of structures. In this paper a passive Rotating Mass Damper (RMD) with negative stiffness characteristic, which was conceptually introduced in an earlier study, ha
Publikováno v:
Journal of Performance of Constructed Facilities. 35
In this study, the construction deficiencies affecting performance of hospitals during the 2017 Sarpol-e Zahab earthquake in Iran were studied through a field survey and numerical assessmen...
Publikováno v:
SN Applied Sciences. 2
Petrochemical plants and industrial facilities have shown high vulnerability during the past earthquakes like Kobe (Japan, 1995), Izmit (Turkey, 1999), Gujarat (India, 2001), Tokachi-Oki (Japan, 2003) and other earthquakes. As more than 50% of the pe
Publikováno v:
Engineering Structures. 172:187-200
The ductility capacity of bridge piers is estimated uniaxially by moment-curvature analysis, regardless of the amount of flexural demand on the perpendicular axis of the section. In this study, by applying a numerical fiber-based model, the ductility