Publikováno v:
IEEE Transactions on Instrumentation and Measurement. 70:1-10
For many industrial applications, corrosion is a life-limiting phenomenon and therefore requires careful consideration and rigorous experimental testing before structural materials can be reliably deployed, particularly in harsh chemical environments
Publikováno v:
IEEE Sensors Journal. 21:498-509
Optical frequency domain reflectometry (OFDR) measurements are performed by recording the interference pattern of light backscattered by density fluctuations or Bragg gratings along the length of an optical fiber. Changes in local temperature or stra
Publikováno v:
Transactions of the American Nuclear Society - Volume 123.
Autor:
Adrian M. Schrell, Kurt A. Terrani, Christian M. Petrie, Brian C. Jolly, Ying Yang, Donovan N. Leonard
Publikováno v:
Journal of Nuclear Materials. 552:153012
Silicon carbide (SiC) components are being considered for a wide range of nuclear applications due to their high-temperature strength retention, low neutron absorption, chemical inertness, and dimensional stability under neutron irradiation. However,
Autor:
Nikita Mukhitov, Aaron L. Glieberman, Qihan Liu, Benjamin D. Pope, Douglas A. Melton, John P. Ferrier, Michael G. Roper, Adrian M. Schrell, Kevin Kit Parker, Adrian Buganza Tepole, John F. Zimmerman, Kevin L. Shores, Jennifer H. R. Kenty
Publikováno v:
Lab Chip
Pancreatic β cell function is compromised in diabetes and is typically assessed by measuring insulin secretion during glucose stimulation. Traditionally, measurement of glucose-stimulated insulin secretion involves manual liquid handling, heterogene
Externí odkaz:
https://explore.openaire.eu/search/publication?articleId=doi_dedup___::d2856ca8c11804415eacfa12d9c70a21
https://europepmc.org/articles/PMC6814249/
https://europepmc.org/articles/PMC6814249/
Publikováno v:
Sensors and Actuators A: Physical. 312:112075
Optical fiber-based sensors are commonly used for industrial monitoring and control processes due to their small size, resistance to electromagnetic interference, and ability to perform a wide variety of high-precision measurements. However, implemen
Publikováno v:
Analytical chemistry. 90(4)
A method for multiplexed sample analysis by mass spectrometry without the need for chemical tagging is presented. In this new method, each sample is pulsed at unique frequencies, mixed, and delivered to the mass spectrometer while maintaining a const
Autor:
Adrian M. Schrell, Michael G. Roper
Publikováno v:
The Analyst. 139:2695-2701
A frequency-modulated fluorescence encoding method was used as a means to increase the number of fluorophores monitored during infrared-mediated polymerase chain reaction. Laser lines at 488 nm and 561 nm were modulated at 73 and 137 Hz, respectively