Zobrazeno 1 - 10
of 135
pro vyhledávání: '"Ab. Halim Abu Bakar"'
Publikováno v:
Energies, Vol 16, Iss 13, p 4902 (2023)
This paper presents a detailed study of the energy savings that can be achieved through residential appliances by implementing conservation voltage reduction (CVR). The computed energy savings are derived from the ZIP coefficients of a load model (st
Externí odkaz:
https://doaj.org/article/535063ca48d94ca29298a3c428a19149
Autor:
Mohamad Norshahrani, Hazlie Mokhlis, Ab. Halim Abu Bakar, Jasrul Jamani Jamian, Shivashankar Sukumar
Publikováno v:
Energies, Vol 10, Iss 11, p 1864 (2017)
The benefits of distributed generation (DG) based on renewable energy sources leads to its high integration in the distribution network (DN). Despite its well-known benefits, mainly in improving the distribution system reliability and security, there
Externí odkaz:
https://doaj.org/article/028c1acae20d4ffe8c75edf4eafa05f5
Autor:
Hazlee Azil Illias, Ming Ming Lim, Ab Halim Abu Bakar, Hazlie Mokhlis, Sanuri Ishak, Mohd Dzaki Mohd Amir
Publikováno v:
PLoS ONE, Vol 16, Iss 7, p e0253967 (2021)
In power system networks, automatic fault diagnosis techniques of switchgears with high accuracy and less time consuming are important. In this work, classification of abnormal location in switchgears is proposed using hybrid gravitational search alg
Externí odkaz:
https://doaj.org/article/91ad42d354074a1c8a506c6a63d92427
Autor:
Kanendra Naidu, Mohd Syukri Ali, Ab Halim Abu Bakar, Chia Kwang Tan, Hamzah Arof, Hazlie Mokhlis
Publikováno v:
PLoS ONE, Vol 15, Iss 1, p e0227494 (2020)
This paper proposes an approach to accurately estimate the impedance value of a high impedance fault (HIF) and the distance from its fault location for a distribution system. Based on the three-phase voltage and current waveforms which are monitored
Externí odkaz:
https://doaj.org/article/05a052027444478e88cc190206212f6b
Publikováno v:
IET Science, Measurement & Technology, Vol 15, Iss 2, Pp 120-129 (2021)
Effective grounding is the most important aspect in every electrical installation because it can ensure efficient equipment operation in the event of electrical faults. Measurement data of soil resistivity is used to assess the suitability of the soi
Autor:
Mohd Syukri Ali, Ab Halim Abu Bakar, Azimah Omar, Amirul Syafiq Abdul Jaafar, Siti Hajar Mohamed
Publikováno v:
Electric Power Systems Research. 216:109064
Publikováno v:
PLoS ONE, Vol 10, Iss 6, p e0129363 (2015)
It is important to predict the incipient fault in transformer oil accurately so that the maintenance of transformer oil can be performed correctly, reducing the cost of maintenance and minimise the error. Dissolved gas analysis (DGA) has been widely
Externí odkaz:
https://doaj.org/article/73b44b7c8b4f401da448aca6f4d71972
Autor:
Muthu Kumaran Gunasegaran, Md Hasanuzzaman, ChiaKwang Tan, Ab Halim Abu Bakar, Vignes Ponniah
Publikováno v:
Sustainability; Volume 14; Issue 20; Pages: 13515
Commercial buildings in Malaysia contribute to 35% of the total electricity demand. During the recent COVID-19 pandemic, the global economy faced a challenging situation that forced many businesses to shut down. However, fast-food restaurants with dr
Autor:
Vladimir Terzija, Hazlee Azil Illias, Syahirah Abd Halim, Nor Hidayah Nor Hassan, Hazlie Mokhlis, Ab Halim Abu Bakar
Publikováno v:
Measurement. 139:103-111
Surge arrester has been proven to be the most effective application to provide optimum lightning protection for the transmission line. Thus, many works on optimizing lightning protection for transmission line have been conducted since the past. Howev
Publikováno v:
2021 IEEE International Conference in Power Engineering Application (ICPEA).
The islanding operation of a distribution network connected with distributed generation may be a useful way to improve its power reliability. However, it requires a good control strategy for ensuring a safe operation of islanded system controlling vo