Publikováno v:
Jurnal Riset Kesehatan, Vol 10, Iss 1, Pp 77-83 (2021)
The projections for the sacrum are axial anteroposterior with the beam 15 degrees toward the cephalad, and axial posteroanterior in the direction of the beam 15 degrees caudally. Some practitioners take steps to examine the sacrum with AP projections
Externí odkaz:
https://doaj.org/article/04adae014b1a44dc92e5a8db57185a16
Publikováno v:
Jurnal Riset Kesehatan, Vol 10, Iss 1, Pp 77-83 (2021)
The projections for the sacrum are axial anteroposterior with the beam 15 degrees toward the cephalad, and axial posteroanterior in the direction of the beam 15 degrees caudally. Some practitioners take steps to examine the sacrum with AP projections
Autor:
Ahlam Issa, Adnan Lahham
Publikováno v:
Health Physics. 120:212-216
This work deals with the evaluation of radiation doses from chest x rays for 240 male and female pediatric patients selected randomly from four Palestinian hospitals. The patient population was divided into five age groups: Newborn, 1, 5, 10, and 15
Publikováno v:
Physica Medica
Physica Medica, Elsevier, 2021, 82, pp.200-210. ⟨10.1016/j.ejmp.2021.01.065⟩
Physica Medica, Elsevier, 2021, 82, pp.200-210. ⟨10.1016/j.ejmp.2021.01.065⟩
The aim of this study is to assess the radiation exposure of the patient and the medical staff during interventional cardiology procedures. Realistic exposure scenarios were developed using the adult reference anthropomorphic phantoms adopted by the
Publikováno v:
Radiation protection dosimetry. 189(4)
Purpose To determine the influence of optimal collimation during lumbar spine radiography on radiation dose and image quality. Material and methods 110 lumbar spine patients were split into two groups—the first imaged with standard collimation and
Publikováno v:
Journal of Clinical Orthopaedics and Trauma. 9:S145-S148
Background Facet joint pain contributes significantly to lower back pain. Image intensifier x-ray guidance is used to locate the facet joints. This can either be in the oblique “Scotty dog” or antero-posterior views. The aim is to investigate whe
Publikováno v:
International Journal of Advanced Engineering Research and Science. 5:160-164
Radiographic image has been used for patient positioning, target localization radiation beam alignment, and subsequent verification of treatment delivery in radiotherapy. Radiographic imaging as all medical use of ionizing radiation can give signific
Autor:
Geoff Dougherty, Takatoshi Toyoda, Idam Arif, Choirul Anam, Naoki Sato, Rena Widita, Toshioh Fujibuchi, Freddy Haryanto
Publikováno v:
Radiation Protection Dosimetry. 179:158-168
The purpose of this study is to establish the relationship between the pixel value (I) of the CT localizer radiograph and water-equivalent thickness (tw) in a straightforward procedure. We used a body CTDI phantom, which was scanned in the AP and LAT
Autor:
Albérico B. Carvalho Júnior, D.C. Galeano, Ademir Xavier da Silva, William S. Santos, Susana O. Souza, Felipe Alan Souza Santos, F. R. Cavalcante
Publikováno v:
Radiation Physics and Chemistry. 140:423-427
Kyphoplasty surgery is widely used for pain relief in patients with vertebral compression fracture (VCF). For this surgery, an X-ray emitter that provides real-time imaging is employed to guide the medical instruments and the surgical cement used to
Publikováno v:
Jurnal Imejing Diagnostik (JImeD). 3:225-230
Background : Many hospitals in the examination of pedis AP projection use 0o or perpendicular. It is not based on the theory. So that, it is done research about the variation of direction angle of AP projection in pedis examination toward anatomy inf