Zobrazeno 1 - 8
of 8
pro vyhledávání: '"A. V. Petryakova"'
Autor:
L. A. Chipiga, A. V. Vodovatov, A. V. Petryakova, I. A. Zvonova, A. A. Stanzhevsky, D. N. Maistrenko, D. A. Vazhenina, D. S. Sysoev
Publikováno v:
Радиационная гигиена, Vol 15, Iss 4, Pp 34-44 (2023)
The development of nuclear medicine technologies in the Russian Federation contributes to the implementation of new diagnostic radiopharmaceuticals in practice. Theranostic pairs such as antibodies and peptides labeled diagnostic and therapeutic radi
Externí odkaz:
https://doaj.org/article/a3f628a041df49feb02830a14c529e83
Autor:
L. A. Chipiga, A. V. Vodovatov, I. A. Zvonova, A. A. Stanzhevsky, A. V. Petryakova, E. E. Anokina, K. S. Velichkina, S. A. Ryzhov
Publikováno v:
Радиационная гигиена, Vol 15, Iss 2, Pp 19-30 (2022)
Radioactive waste management is a modern-day issue in terms of radiation safety due to the development of radionuclide therapy, the emergence of new radiopharmaceuticals, radionuclides, and treatment methods, which allow for radionuclide therapy in a
Externí odkaz:
https://doaj.org/article/bafb69d20b9c4953afb2a1a48b0e4de0
Autor:
Aleksandr V. Vodovatov, Larisa A. Chipiga, Polina S. Druzhinina, Ilya G. Shatskiy, Anastasiya V. Petryakova, Svetlana S. Sarycheva, Artem M. Biblin, Rustam R. Akhmatdinov, Ruslan R. Akhmatdinov, Yuliya N. Kapyrina, Anzhelika A. Bratilova, Ilya V. Soldatov, Zoya A. Lantukh, Viktor G. Puzyrev, Sergey A. Ryzhov
Publikováno v:
Digital Diagnostics, Vol 4, Iss 3, Pp 322-339 (2023)
The form of federal governmental statistical surveillance № 3-DOZ, titled “Data on patient doses from medical X-ray examinations,” has changed significantly by the order of Rosstat N 880. In particular, the structure of the form’s has been re
Externí odkaz:
https://doaj.org/article/868984052267463b88c9b27aa1fe31ba
Autor:
A. A. Stanzhevskii, D. N. Maistrenko, D. A. Vazhenina, D. S. Sysoev, A. V. Vodovatov, L. A. Chipiga, S. A. Ryzhov, A. V. Petryakova
Publikováno v:
Diagnostic radiology and radiotherapy. 13:16-26
At the present time three most common approaches are used for the planning of the radionuclide therapy: administration of the fixed activity of radionuclide in radiopharmaceutical, or administration of activity normalized per unit of body mass or bod
Autor:
A. V. Vodovatov, L. A. Chipiga, A. V. Petryakova, A. A. Stanzhevskii, D. N. Maistrenko, D. A. Vazhenina, D. S. Sysoev, S. A. Ryzhov
Publikováno v:
Diagnostic radiology and radiotherapy. 13:9-15
Existing drawbacks of the radionuclide therapy planning may lead to the excessive irradiation of the healthy organs and tissues that is associated with the development of deterministic and stochastic effects. In some cases absorbed dose in region of
Autor:
M. M. Kulagina, E. V. Petryakova, A. P. Vasil’ev, M. A. Bobrov, V. A. Belyakov, Nikolai A. Maleev, S. N. Maleev, I. V. Makartsev, Yu. P. Kudryashova, F. A. Ahmedov, S. I. Troshkov, V. M. Ustinov, S. A. Blokhin, A. G. Fefelov, E. L. Fefelova, A. V. Egorov, A. G. Kuzmenkov
Publikováno v:
Technical Physics Letters. 45:1092-1096
A high-electron-mobility transistor (HEMT) based on InAlAs/InGaAs/InP heterostructures possessing higher breakdown characteristics is developed. An InGaAs composite channel structure, combined with completely selective forming of the double recess st
Autor:
A. V. Korotkov, T. A. Shobolova, S. V. Obolensky, A. S. Puzanov, E. V. Petryakova, Vladimir Kozlov, A. V. Lipatnikov
Publikováno v:
Semiconductors. 53:1353-1356
Approaches to solving the problem of the development of efficient bipolar and heterobipolar transistors operating at radio- and ultrahigh frequencies (0.1–10 GHz), which could be used as active elements of modern Si-based and GaAs-based radiation-r
Autor:
Y. N. Priporova, A. V. Petryakova, G. M. Mitusova, T. M. Rakova, M. S. Tlostanova, L. A. Chipiga, Ivanova Aa, I. A. Kotomin, D. V. Ryzhkova, V. Y. Sukhov, I. V. Boikov, E. M. Zykov
Publikováno v:
7TH INTERNATIONAL CONFERENCE ON X-RAY, ELECTROVACUUM AND BIOMEDICAL TECHNIQUE.
Quantitative assessment of diagnostic PET images must be accurate, repeatable, and reproducible on different PET scanners. Hence, it is necessary to develop a simple quality control (QC) method which will be widely available. This study was to assess