Zobrazeno 1 - 10
of 25
pro vyhledávání: '"A. Puttarach"'
Autor:
Ruangchai Juwattanasamran, Seksan Songchanthuek, Darush Struss, Orapin Saritnum, Kedsadaporn Junta, Jumrearn Puttarach, Prawit Puddhanon
Publikováno v:
Chiang Mai University Journal of Natural Sciences. 19:155-162
Autor:
Wirat Nakkrongdee, Arwut Puttarach, Sakorn Panta, T. Kasirawat, Chotepong Pongsriwat, Att Phayomhom
Publikováno v:
2020 17th International Conference on Electrical Engineering/Electronics, Computer, Telecommunications and Information Technology (ECTI-CON).
This paper presents a technique for grounding system design in a small area distribution substation. Compression ratio adjustment in order to decrease touch voltage is hard to design with this situation due to the limitation of area. Furthermore, thi
Autor:
PUTTARACH, J.1 jumrearnp@yahoo.com, PUDDHANON, P.1, SIRIPIN, S.1, SANGTONG, V.2, SONGCHANTUEK, S.3
Publikováno v:
SABRAO Journal of Breeding & Genetics. Mar2016, Vol. 48 Issue 1, p72-79. 8p.
Publikováno v:
2014 International Electrical Engineering Congress (iEECON).
The Back flashover generated from a lightning stroke hit on an overhead ground wire (OHGW) or a pole top is one of the major causes of sustained interruption in Metropolitan Electricity Authority (MEA)'s distribution system. One effective way to redu
Publikováno v:
2014 International Electrical Engineering Congress (iEECON).
The study provides comparison of grounding performance between square and rectangle ground grid, when given the same size of area of coverage. The result shows that the rectangle ground grid possesses better grounding performance than the square one.
Publikováno v:
2014 International Electrical Engineering Congress (iEECON).
This paper proposes characteristic of uniform (homogeneous) soil and grounding performance assessment which consist of ground potential rise (GPR), touch voltage and step voltage of ground grid buried in 0.5 m depth of uniform and two-layer soil. The
Publikováno v:
2007 IEEE Lausanne Power Tech.
This paper presents a substation grounding grid analyzed with the variation of soil layer depth. The grounding grid system of a practical 22 kV substation, in which the ground grid is made from copper, is calculated by virtue of the CDEGS software. T
Publikováno v:
2014 International Electrical Engineering Congress (iEECON); 2014, p1-4, 4p
Publikováno v:
2014 International Electrical Engineering Congress (iEECON); 2014, p1-4, 4p
Publikováno v:
2014 International Electrical Engineering Congress (iEECON); 2014, p1-4, 4p