Zobrazeno 1 - 7
of 7
pro vyhledávání: '"A. M. Khizbullin"'
Autor:
A. Yu. Turusov, A. M. Khizbullin, K. B. Veshnyakov, A. N. Lepekhin, A. N. Sokolov, V. I. Polunichev, V. M. Belyaev, A. N. Pakhomov, M. A. Bol’shukhin
Publikováno v:
Atomic Energy. 129:27-34
The main stages of the origination (in our country) of the world’s first floating nuclear thermal power plant based on the floating power-generating unit Akademik Lomonosov with two icebreaker-type reactor installations whose chief designer and com
Publikováno v:
Atomic Energy. 125:165-171
The basic results of computational and experimental studies of passive systems of emergency heat removal in application to ship and portable reactor facilities are presented. The methodological correlations for calculations of heat removal systems wi
Publikováno v:
Atomic Energy. 123:1-9
Severe accidents in NPP with VVER can be accompanied by hydrogen entering the containment space. The aim of the present work is an experimental and computational study of the possibility of hydrogen stratification in the containment in a scenario rep
Autor:
V. D. Lychakov, V. A. Il’in, A. M. Khizbullin, A. N. Sokolov, S. V. Svetlov, B. F. Balunov, A. A. Shcheglov
Publikováno v:
Thermal Engineering. 59:20-25
Results of an experimental study of void fraction φ in two vertical tubes of different diameters and lengths under low pressure of steam-water flow are presented. The region of high values of φ is considered. Generalizing correlations are presented
Autor:
M. A. Bol’shukhin, B. F. Balunov, E. N. Saikova, A. A. Shcheglov, A. M. Khizbullin, V. A. Il’in, A. N. Sokolov, O. A. Bykh
Publikováno v:
Thermal Engineering. 58:418-423
Results from thermal-hydraulic tests of a full-scale module of the emergency cooldown system for a KLT-40S reactor installation are presented. The validity of the solutions adopted in its design is shown. Recommendations for calculating the heat tran
Publikováno v:
Atomic Energy. 108:343-348
In the designs of the new-generation reactor facilities, including floating nuclear heat and electricity plants, new passive containment safety systems are used to increase operational safety. The objective of the present work is to validate experime
Autor:
V. V. Bezlepkin, S. E. Semashko, V. V. Vakhrushev, M. A. Bol’shukhin, O. V. Makarov, I. M. Ivkov, A. M. Khizbullin, A. M. Bakhmet’ev
Publikováno v:
Atomic Energy. 106:185-190
Equipping new-generation nuclear power plants with passive means for controlling unanticipated accidents is one of the most promising directions for increasing safety, which is being implemented in the AES-2006 design for the site of the Leningradska