Zobrazeno 1 - 10
of 114
pro vyhledávání: '"A. Loupilov"'
Publikováno v:
In Nuclear Inst. and Methods in Physics Research, A 2007 576(1):80-82
Autor:
Owens, Alan, Buslaps, T., Gostilo, V., Graafsma, H., Hijmering, R., Kozorezov, A., Loupilov, A., Lumb, D., Welter, E.
Publikováno v:
In Nuclear Inst. and Methods in Physics Research, A 2006 563(1):242-248
Autor:
Owens, Alan *, Peacock, A., Bavdaz, M., Brammertz, G., Dubeckỳ, F., Gostilo, V., Gryaznov, D., Haack, N., Krumrey, M., Loupilov, A.
Publikováno v:
In Nuclear Inst. and Methods in Physics Research, A 2002 491(3):444-451
Autor:
Owens, A., den Hartog, R., Quarati, F., Gostilo, V., Kondratjev, V., Loupilov, A., Kozorezov, A. G., Wigmore, J. K., Webb, A., Welter, E.
Publikováno v:
Journal of Applied Physics; 9/1/2007, Vol. 102 Issue 5, p054505, 9p, 1 Diagram, 1 Chart, 10 Graphs
Autor:
Marek Moszynski, D. Wolski, A. Syntfeld, A. Loupilov, R. Arlt, Vladimir Gostilo, A. Nassalski, M. Swoboda
Publikováno v:
IEEE Transactions on Nuclear Science. 53:3938-3943
The performance of hand-held radioisotope identification devices (RIDs) is still hampered by the performance of the NaI(Tl) detectors, which are commonly used in such instruments. In this paper, we continue the search for better detector options. One
Publikováno v:
Microchimica Acta. 155:285-288
The results of the development of electrically cooled SiLi detectors are presented for applications in X-ray equipment. The characteristics of such detectors compare well with those of the detectors cooled by liquid nitrogen, and to obtain these char
Akademický článek
Tento výsledek nelze pro nepřihlášené uživatele zobrazit.
K zobrazení výsledku je třeba se přihlásit.
K zobrazení výsledku je třeba se přihlásit.
Publikováno v:
X-Ray Spectrometry. 33:462-465
We discuss recent results obtained in the development of Si(Li), Si p–i–n, CdTe p–i–n and CdZnTe x-ray detectors with Peltier coolers for fabrication of laboratory and portable XRF analyzers. The characteristics of Si(Li) Peltier-cooled detec
Autor:
F. Dubeckỳ, A. Loupilov, Anthony J. Peacock, Guy Brammertz, Vladimir Gostilo, Marcos Bavdaz, D. Gryaznov, N. Haack, Michael Krumrey, Alan Owens
Publikováno v:
Nuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment. 491:444-451
In this, the second part of a detailed study into the X-ray response of InP, we present results of a series of X-ray measurements on a 3.142 mm 2 � 180mm thick semi-insulating InP detector at the BESSY II and HASYLAB synchrotron radiation research
Autor:
Vladimir Gostilo, D. Gryaznov, A. Loupilov, Heikki Sipila, Anthony J. Peacock, Marcos Bavdaz, Alan Owens
Publikováno v:
Nuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment. 487:435-440
We present the results of X-ray measurements on a prototype InP detector. The device was fabricated from Fe-doped bulk material of size 3 � 3 � 0.18 mm 3 . X-ray measurements have been carried out using a number of radioactive and fluorescent tar