S. Yasumura, R.I. Moore, D.A. Weber, Pierson Rn, Skelany R, F.A. Dilmanian, A. F. LoMonte, Zhao M, Ruimei Ma
Publikováno v:
Health Physics. 72:443-449
An artificial skeleton was designed and placed inside a bottle manikin absorber phantom to provide a new reference standard for measurements of total body calcium by in vivo neutron activation analysis at Brookhaven National Laboratory. The compositi
Publikováno v:
The American Journal of Clinical Nutrition. 53:1339-1344
Total body carbon (TBC) is measured in vivo by neutron inelastic scattering. The fast neutrons needed for the irradiation are produced by a miniature deuterium-tritium (D-T) neutron generator. Body fat and protein are the main contributors to TBC. Bo
Publikováno v:
Applied radiation and isotopes : including data, instrumentation and methods for use in agriculture, industry and medicine. 49(5-6)
Total body chlorine (TBCl), used to estimate the extracellular space, is measured by delayed-gamma neutron activation (DGNA) using the reaction 37 Cl(n,γ) 38 Cl, at Brookhaven National Laboratory. During the calibration process, we noticed that diff
Autor:
A. F. LoMonte, X. Zhao, F.A. Dilmanian, H.M. Rarback, R.I. Moore, K.A. Vodopia, Ruimei Ma, Richard N. Pierson, S. Yasumura, D.A. Weber
Publikováno v:
Applied radiation and isotopes : including data, instrumentation and methods for use in agriculture, industry and medicine. 49(5-6)
Differences in body size and shape can cause large variances in the results of in vivo neutron activation analysis. Preliminary body-size correction data were obtained for the delayed-gamma neutron activation facility (DGNA) at Brookhaven National La
Autor:
S, Yasumura, D, Glaros, J, Kalef-Ezra, J, Xatzikonstantinou, A F, LoMonte, J K, Yeh, R I, Moore
Publikováno v:
Basic life sciences. 55
Autor:
J. K. Yeh, John Kalef-Ezra, John Xatzikonstantinou, R. I. Moore, S. Yasumura, D. Glaros, A. F. LoMonte
Publikováno v:
In Vivo Body Composition Studies ISBN: 9781461287803
Textbook values for the size of the extracellular water compartment (ECW) expressed as a fraction of total body water (TBW): ECW/TBW, range from .27 to .45 (Berne and Levy. 1988). These discrepancies are disturbing since the size of the ECW and intra
Externí odkaz:
https://explore.openaire.eu/search/publication?articleId=doi_________::bb9cedff27d4df300b84a5dc45870317
https://doi.org/10.1007/978-1-4613-1473-8_49
https://doi.org/10.1007/978-1-4613-1473-8_49
Publikováno v:
Patient Education and Counseling. 23:S137
Publikováno v:
Medical Physics. 13:45-49
A technique has been developed for in vivo determination of lithium content in the head (and potentially in the whole body and in selected organs) of patients undergoing lithium therapy. It is based on the measurement of tritium induced by the 6Li(n,