Zobrazeno 1 - 10
of 1 378
pro vyhledávání: '"A, Morozzi"'
Autor:
Menichelli, M., Aziz, S., Bashiri, A., Bizzarri, M., Buti, C., Calcagnile, L., Calvo, D., Caprai, M., Caputo, D., Caricato, A. P., Catalano, R., Cazzanelli, M., Cirio, R., Cirrone, G. A. P., Cittadini, F., Croci, T., Cuttone, G., de Cesare, G., De Remigis, P., Dunand, S., Fabi, M., Frontini, L., Grimani, C., Guarrera, M., Hasnaoui, H., Ionica, M., Kanxheri, K., Large, M., Lenta, F., Liberali, V., Lovecchio, N., Martino, M., Maruccio, G., Maruccio, L., Mazza, G., Monteduro, A. G., Morozzi, A., Nascetti, A., Pallotta, S., Papi, A., Passeri, D., Pedio, M., Petasecca, M., Petringa, G., Peverini, F., Placidi, P., Polo, M., Quaranta, A., Quarta, G., Rizzato, S., Sabbatini, F., Servoli, L., Stabile, A., Talamonti, C., Thomet, J. E., Mora, M. S. Vasquez, Villani, M., Wheadon, R. J., Wyrsch, N., Zema, N., Tosti, L.
Radiation damage tests in hydrogenated amorphous silicon (a-Si:H) flexible flux and dose-measuring devices have been performed with a 3 MeV proton beam, to evaluate combined displacement and total ionizing dose damage. The tested devices had two diff
Externí odkaz:
http://arxiv.org/abs/2412.13124
Autor:
Menichelli, M., Antognini, L., Aziz, S., Bashiri, A., Bizzarri, M., Calcagnile, L., Caprai, M., Caputo, D., Caricato, A. P., Catalano, R., Chilà, D., Cirrone, G. A. P., Croci, T., Cuttone, G., De Cesare, G., Dunand, S., Fabi, M., Frontini, L., Grimani, C., Ionica, M., Kanxheri, K., Large, M., Liberali, V., Lovecchio, N., Martino, M., Maruccio, G., Mazza, G., Monteduro, A. G., Morozzi, A., Moscatelli, F., Nascetti, A., Pallotta, S., Papi, A., Passeri, D., Pedio, M., Petasecca, M., Petringa, G., Peverini, F., Piccolo, L., Placidi, P., Quarta, G., Rizzato, S., Rossi, G., Sabbatini, F., Servoli, L., Stabile, A., Talamonti, C., Thomet, J. E., Tosti, L., Villani, M., Wheadon, R. J., Wyrsch, N., Zema, N.
Hydrogenated amorphous silicon (a-Si:H) is a material having an intrinsically high radiation hardness that can be deposited on flexible substrates like Polyimide. For these properties a-Si:H can be used for the production of flexible sensors. a-Si:H
Externí odkaz:
http://arxiv.org/abs/2310.00495
Autor:
Grimani, Catia, Fabi, Michele, Sabbatini, Federico, Villani, Mattia, Calcagnile, Lucio, Caricato, Anna Paola, Catalano, Roberto, Cirrone, Giuseppe Antonio Pablo, Croci, Tommaso, Cuttone, Giacomo, Dunand, Sylvain, Frontini, Luca, Ionica, Maria, Kanxheri, Keida, Large, Matthew, Liberali, Valentino, Martino, Maurizio, Maruccio, Giuseppe, Mazza, Giovanni, Menichelli, Mauro, Monteduro, Anna Grazia, Morozzi, Arianna, Moscatelli, Francesco, Pallotta, Stefania, Passeri, Daniele, Pedio, Maddalena, Petasecca, Marco, Petringa, Giada, Peverini, Francesca, Piccolo, Lorenzo, Placidi, Pisana, Quarta, Gianluca, Rizzato, Silvia, Stabile, Alberto, Talamonti, Cinzia, Wheadon, Richard James, Wyrsch, Nicolas, Servoli, Leonello
The characteristics of a hydrogenated amorphous silicon (a-Si:H) detector are presented here for monitoring in space solar flares and the evolution of large energetic proton events up to hundreds of MeV. The a-Si:H presents an excellent radiation har
Externí odkaz:
http://arxiv.org/abs/2302.00339
Autor:
Cartiglia, N., Moscatelli, F., Arcidiacono, R., Asenov, P., Costa, M., Croci, T., Ferrero, M., Fondacci, A., Lanteri, L., Menzio, L., Morozzi, A., Mulargia, R., Passeri, D., Siviero, F., Sola, V., Tornago, M.
Two design innovations, low-gain avalanche (Low-Gain Avalance Diode, LGAD) and resistive read-out (Resistive Silicon Detector, RSD), have brought strong performance improvements to silicon sensors. Large signals, due to the added gain mechanism, lead
Externí odkaz:
http://arxiv.org/abs/2301.02968
Autor:
Menichelli, M., Bizzarri, M., Calcagnile, L., Caprai, M., Caricato, A. P., Catalano, R., Cirrone, G. A. P., Croci, T., Cuttone, G., Dunand, S., Fabi, M., Frontini, L., Gianfelici, B., Grimani, C., Ionica, M., Kanxheri, K., Large, M., Liberali, V., Martino, M., Maruccio, G., Mazza, G., Monteduro, A. G., Morozzi, A., Moscatelli, F., Pallotta, S., Papi, A., Passeri, D., Pedio, M., Petasecca, M., Petringa, G., Peverini, F., Piccolo, L., Placidi, P., Quarta, G., Rizzato, S., Rossi, G., Sabbatini, F., Stabile, A., Servoli, L., Talamonti, C., Villani, M., Wheadon, R. J., Wyrsch, N.
The HASPIDE (Hydrogenated Amorphous Silicon PIxels DEtectors) project aims at the development of thin hydrogenated amorphous silicon (a-Si:H) detectors on flexible substrates (mostly Polyimide) for beam monitoring, neutron detection and space applica
Externí odkaz:
http://arxiv.org/abs/2211.17114
Autor:
Alessandro Zappi, Alessandra Biancolillo, Nicholas Kassouf, Valentina Marassi, Pietro Morozzi, Laura Tositti, Dora Melucci
Publikováno v:
Analytica, Vol 5, Iss 2, Pp 219-232 (2024)
A novel approach for the quantification of recycled polyethylene terephthalate (r-PET) in commercial bottles is presented. Fifty-eight bottle samples from several brands and producers containing different percentages of r-PET were purchased from the
Externí odkaz:
https://doaj.org/article/7c0a2484d71540f3926f50997022d801
Autor:
Sola, Valentina, Arcidiacono, Roberta, Asenov, Patrick, Borghi, Giacomo, Boscardin, Maurizio, Cartiglia, Nicolò, Vignali, Matteo Centis, Croci, Tommaso, Ferrero, Marco, Fondacci, Alessandro, Gioachin, Giulia, Giordanengo, Simona, Lantieri, Leonardo, Mandurrino, Marco, Menzio, Luca, Monaco, Vincenzo, Morozzi, Arianna, Moscatelli, Francesco, Passeri, Daniele, Pastrone, Nadia, Paternoster, Giovanni, Siviero, Federico, Staiano, Amedeo, Tornago, Marta
Publikováno v:
Nuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment, Volume 1040, 2022, 167232
In this contribution, we present an innovative design of the Low-Gain Avalanche Diode (LGAD) gain layer, the p$^+$ implant responsible for the local and controlled signal multiplication. In the standard LGAD design, the gain layer is obtained by impl
Externí odkaz:
http://arxiv.org/abs/2209.00494
Autor:
Evangelos Daskalakis, Neelam Iqbal, Sarathkumar Loganathan, Emilio Spettoli, Giacomo Morozzi, Alberto Ballardini, Peter V. Giannoudis, Animesh Jha
Publikováno v:
Materials & Design, Vol 245, Iss , Pp 113243- (2024)
The restoration of critical-size load-bearing bone defects calls for the application of bioactive scaffolds that are regenerative, osteoconductive, and demonstrate mechanical strength comparable with natural bone. Novel hydroxyapatite (HAp) scaffolds
Externí odkaz:
https://doaj.org/article/33db2fd3bf0f43f597494771f481530a
Publikováno v:
In Journal of the Mechanical Behavior of Biomedical Materials December 2024 160
Autor:
Morozzi, A., Fondacci, A., Croci, T., Arcidiacono, R., Boscardin, M., Cartiglia, N., Vignali, M. Centis, Ferrero, M., Lanteri, L., Menzio, L., Paternoster, G., Siviero, F., White, R., Moscatelli, F., Passeri, D., Sola, V.
Publikováno v:
In Nuclear Inst. and Methods in Physics Research, A December 2024 1069