Zobrazeno 1 - 10
of 82
pro vyhledávání: '"3D GRASE"'
Publikováno v:
Magnetic Resonance Imaging. 102:141-150
Purpose: The consensus for the clinical implementation of arterial spin labeling (ASL) perfusion imaging recommends a segmented 3D Gradient and Spin-Echo (GRASE) readout for optimal signal-to-noise-ratio (SNR). The correction of the associated suscep
Publikováno v:
NeuroImage, Vol 220, Iss , Pp 117095- (2020)
Magnetic resonance imaging (MRI)-based quantification of the blood-oxygenation-level-dependent (BOLD) effect allows oxygen extraction fraction (OEF) mapping. The multi-parametric quantitative BOLD (mq-BOLD) technique facilitates relative OEF (rOEF) m
Externí odkaz:
https://doaj.org/article/6090bbe3488c477fadefe8447a1db1b3
Autor:
Domingos, Catarina, Fouto, Ana R., Nunes, Rita G., Ruiz-Tagle, Amparo, Esteves, Inês, Silva, Nuno A., Vilela, Pedro, Gil-Gouveia, Raquel, Figueiredo, Patrícia
Purpose: The consensus for the clinical implementation of arterial spin labeling (ASL) perfusion imaging recommends a segmented 3D Gradient and Spin-Echo (GRASE) readout for optimal signal-to-noise-ratio (SNR). The correction of the associated suscep
Externí odkaz:
https://explore.openaire.eu/search/publication?articleId=od______2020::78e34823d3e53be1c15a62dce5c59af1
https://hdl.handle.net/10400.14/41674
https://hdl.handle.net/10400.14/41674
Akademický článek
Tento výsledek nelze pro nepřihlášené uživatele zobrazit.
K zobrazení výsledku je třeba se přihlásit.
K zobrazení výsledku je třeba se přihlásit.
Akademický článek
Tento výsledek nelze pro nepřihlášené uživatele zobrazit.
K zobrazení výsledku je třeba se přihlásit.
K zobrazení výsledku je třeba se přihlásit.
Akademický článek
Tento výsledek nelze pro nepřihlášené uživatele zobrazit.
K zobrazení výsledku je třeba se přihlásit.
K zobrazení výsledku je třeba se přihlásit.
Autor:
Tetiana Dadakova, Alexander Beckett, Suhyung Park, Jennifer Townsend, Laurentius Huber, David A. Feinberg
Publikováno v:
Magn Reson Med
Magnetic Resonance in Medicine, 84(6), 3128-3145. Wiley
Magnetic Resonance in Medicine, 84(6), 3128-3145. Wiley
Purpose: Functional MRI (fMRI) at the mesoscale of cortical layers and columns requires both sensitivity and specificity, the latter of which can be compromised if the imaging method is affected by vascular artifacts, particularly cortical draining v
Autor:
Fabien C Schneider, Tobias Kober, Tom Hilbert, Pierre Croisille, Josef Pfeuffer, Bénédicte Maréchal, Magalie Viallon, Thomas Troalen, Manjunathan Nanjappa
Publikováno v:
Magnetic Resonance Materials in Physics, Biology and Medicine. 34:437-450
In this perfusion magnetic resonance imaging study, the performances of different pseudo-continuous arterial spin labeling (PCASL) sequences were compared: two-dimensional (2D) single-shot readout with simultaneous multislice (SMS), 2D single-shot ec
Publikováno v:
Magnetic Resonance in Medicine, 86(3), 1454-1462. WILEY
Magnetic Resonance in Medicine
Repositório Institucional da USP (Biblioteca Digital da Produção Intelectual)
Universidade de São Paulo (USP)
instacron:USP
Magnetic Resonance in Medicine
Repositório Institucional da USP (Biblioteca Digital da Produção Intelectual)
Universidade de São Paulo (USP)
instacron:USP
Purpose: To monitor the complete passage of the labeled blood through the vascular tree into tissue and improve the quantification of ASL maps, we evaluated the effect of 3D gradient and spin -echo (GRASE) readout segments on temporal SNR (tSNR) and
Externí odkaz:
https://explore.openaire.eu/search/publication?articleId=doi_dedup___::22c9eafcf47b422c1b4d253f0e6f8cf8
http://hdl.handle.net/1887/3277430
http://hdl.handle.net/1887/3277430
Purpose To monitor the complete passage of the labeled blood through the vascular tree into tissue and improve the quantification of ASL maps, we evaluated the effect of 3D gradient and spin-echo (GRASE) readout segments on temporal SNR (tSNR) and im
Externí odkaz:
https://explore.openaire.eu/search/publication?articleId=od_______202::a1db740126576359097b86580e31d9d6