Zobrazeno 1 - 10
of 58
pro vyhledávání: '"柱梁接合部"'
Publikováno v:
日本建築学会構造系論文集. 80(713):1045-1053
This paper presents a method of evaluating local damage in steel beam-column connections using dynamic strain responses measured under ambient vibrations. In the proposed method, inner-force distribution in steel beam-column connection was estimated
Publikováno v:
日本建築学会技術報告集. 19(43):917-922
Loading tests were conducted using column-beam joint specimens with such a shear-bending capacity ratio in the panel zone as specified for practical design. 1) The Q-R curve indicated stable and ductile hysteresis with no rapid strength reduction bey
Publikováno v:
日本建築学会構造系論文集. 77(682):1951-1958
This paper presents results of full-scale loading tests of welded moment connections subjected to variable amplitude cyclic loadings. The tests were conducted by two types of loading protocols, i.e. the two different constant amplitudes and the rando
Publikováno v:
日本建築学会構造系論文集. 77(682):1959-1968
This paper presents results of loading tests of H-SA700 high strength steel structures in which beams and columns are made by undermatched welds and constructed by knee brace dampers. The feasibility of high strength bolted joints of high strength st
Autor:
TAKATSUKA, Kouhei, MANABE, Yoshiki, SUITA, Keiichiro, TANAKA, Tsuyoshi, TSUKADA, Takaaki, SU, Zhongyu
Publikováno v:
日本建築学会構造系論文集. 77(673):453-459
This paper presents results of full-scale cyclic loading tests under constant deformation amplitude conducted to evaluate deformation capacity of welded beam-to-column connection adopted in a moment frame. Test specimens are designed and fabricated t
Publikováno v:
日本建築学会技術報告集. 18(40):907-912
In this study, the structural performance of fully precast reinforced concrete beam-column joints was examined by conducting loading tests while varying the shear capacity in the panel zone, anchorage capacity of reinforcing bars of beam and the rati
Publikováno v:
日本建築学会技術報告集. 18(39):529-534
Research and development on a new precast concrete system that beam-column joints are manufactured as the precast concrete has been conducted for the purpose of more efficient use of precast concrete technology. In this study, the loading test is con
Autor:
SUITA, Keiichiro, TANAKA, Tsuyoshi, SATO, Atsushi, MANABE, Yoshiki, TSUKADA, Takaaki, SU, Zhongyu
Publikováno v:
日本建築学会構造系論文集. 76(664):1135-1142
This paper presents results of full-scale cyclic loading tests under constant deformation amplitude conducted to evaluate deformation capacity of welded beam-to-column connection adopted in moment frames. Test specimens are designed and fabricated to