Zobrazeno 1 - 10
of 46
pro vyhledávání: '"Šantić, Ante"'
Publikováno v:
In Measurement 2000 27(2):121-131
Autor:
Melinščak, Martina, Šantić, Ante
Measurement of tissue volume changes by voltage pulse plethysmography is being studied. In voltage pulse plethysmography short voltage pulses activate the bio-tissue and the characteristics of the transient process are measured. There are two possibl
Externí odkaz:
https://explore.openaire.eu/search/publication?articleId=57a035e5b1ae::f1f57515c2bf513a52338c0596bc6b73
https://www.bib.irb.hr/308744
https://www.bib.irb.hr/308744
This capacitive transducer is developed for force measurement in the legs. For this purpose transducer has to be flat, fixed under the shoes on the sole, with a linear force to voltage characteristic. Because the stress on the metatarsal part of the
Externí odkaz:
https://explore.openaire.eu/search/publication?articleId=57a035e5b1ae::d3802b1dc0d80d8a3c8ccc6ccc068e7c
https://www.bib.irb.hr/3727
https://www.bib.irb.hr/3727
Three capacitive sensors are made flat for three components of force measurement on the shoe sole. A special sensor based on infrared radiation changes in the crutches was developed. The measured forces are presented on the monitor during the normal
Externí odkaz:
https://explore.openaire.eu/search/publication?articleId=57a035e5b1ae::4f754eef5784e0fb9aed69f47993c675
https://www.bib.irb.hr/243277
https://www.bib.irb.hr/243277
This paper deals with a force measurement device that is applied in real and for training cardiopulmonary resuscitation. The measured force is shown on the computer monitor and the obtained data can be stored. To fulfill the requirement that it has t
Externí odkaz:
https://explore.openaire.eu/search/publication?articleId=57a035e5b1ae::0591a2d0cf799f3b7d4a05465bca67d0
https://www.bib.irb.hr/71590
https://www.bib.irb.hr/71590
Autor:
Bilas, Vedran, Šantić, Ante
Optical transmission can be a successful alternative to radio for mobile indoor wireless links. For biomedical mobile telemetry applications a low power consumption and lightweight of a wearable transmitter, together with reliable operation over a wi
Externí odkaz:
https://explore.openaire.eu/search/publication?articleId=57a035e5b1ae::f776f896872e742bd83ecc8341ecafcb
https://www.bib.irb.hr/71036
https://www.bib.irb.hr/71036
Mjerni sustav za ispitivanje vertikalnih reaktivnih sila pri normalonom i patološkom hodu
Externí odkaz:
https://explore.openaire.eu/search/publication?articleId=57a035e5b1ae::0f25cea70b58dcde9842156cc6dec5f0
https://www.bib.irb.hr/72904
https://www.bib.irb.hr/72904
Autor:
Kovačić, Dubravko, Šantić, Ante
In Electrical Impedance Tomography (EIT) measurement sinusoidal currents are applied on a surface of the human body and voltage response is measured in order to reconstruct conductivity distribution in a body cross-section. We have constructed an exp
Externí odkaz:
https://explore.openaire.eu/search/publication?articleId=57a035e5b1ae::c3e2bbf0d73d4b46a6aac2d17b2a2de8
https://www.bib.irb.hr/71589
https://www.bib.irb.hr/71589
Autor:
Kovačić, Dubravko, Šantić, Ante
Instead of sinusoidal current pattern for determine the resistive component of impedance, short current pulses are used and voltage responses are measured. An experimental tomography system with 16 electrodes is developed. Measurements are obtained i
Externí odkaz:
https://explore.openaire.eu/search/publication?articleId=57a035e5b1ae::33d477af1c8be14d0050c72a2a2d2ccc
https://www.bib.irb.hr/71609
https://www.bib.irb.hr/71609
Autor:
Lacković, Igor, Šantić, Ante
For blood pressure measurement in finger a combined measurement method was developed. The method is based on the usage of an air-filled finger cuff for occlusion of proximal finger arteries and a pulse sensor placed at the fingertip for detecting dis
Externí odkaz:
https://explore.openaire.eu/search/publication?articleId=57a035e5b1ae::bd6151bf5079dd21b87288c4defe68d9
https://www.bib.irb.hr/71562
https://www.bib.irb.hr/71562