Tomography, Vol 8, Iss 1, Pp 303-315 (2022)
(1) Background: The aim of this study was to determine the frequency and the pattern of post-procedural intracranial aneurysm contrast enhancement on high-resolution vessel wall magnetic resonance imaging (HR-VW MRI). We investigated the possible ass
Externí odkaz:
https://doaj.org/article/f62f2431b9ca49879150e54e0aa4d1f7
Autor:
Wioletta Pawlukowska, Krystian Mross, Marta Jankowska, Łukasz Zwarzany, Wojciech Poncyljusz, Marta Masztalewicz
Publikováno v:
Brain Sciences, Vol 13, Iss 4, p 603 (2023)
The diagnosis of internal carotid artery dissection (ICAD) at the stage of local signs is essential in the prevention of the life-treating cerebral complication; however, making this diagnosis has significant difficulties. We present the case of a 36
Externí odkaz:
https://doaj.org/article/d3bab00b68e7402db40430e0d5655c7d
Publikováno v:
Neurologia i Neurochirurgia Polska. 54:518-523
Introduction. The prevalence of intracranial aneurysms is estimated to be around 3% in the general population. Although these are often incidental findings, they potentially carry the risk of rupture, with all of the devastating consequences of SAH.
Publikováno v:
Tomography; Volume 8; Issue 1; Pages: 303-315
(1) Background: The aim of this study was to determine the frequency and the pattern of post-procedural intracranial aneurysm contrast enhancement on high-resolution vessel wall magnetic resonance imaging (HR-VW MRI). We investigated the possible ass
Autor:
Krzysztof Kościukiewicz, Łukasz Zwarzany, Leszek Sagan, Michał Gębka, Marcin Sawicki, Kornelia Grabizna, Kornel Chełstowski, Piotr Gołofit, Michał M. Skoczylas, Dariusz Jeżewski, Wojciech Poncyljusz, Katarzyna Kołaczyk
Publikováno v:
Neurologia i neurochirurgia polska. 54(1)
Background. In patients with SAH and multiple aneurysms, the ruptured lesion must be identified to prevent recurrent bleeding. Aim of the study. To assess the diagnostic value of non-enhanced computed tomography (NECT) in identifying the rupture site
Publikováno v:
Journal of Clinical Medicine, Vol 10, Iss 225, p 225 (2021)
Journal of Clinical Medicine
Volume 10
Issue 2
Journal of Clinical Medicine
Volume 10
Issue 2
Background: We decided to investigate whether aneurysm wall enhancement (AWE) on high-resolution vessel wall magnetic resonance imaging (HR VW-MRI) coexists with the conventional risk factors for aneurysm rupture. Methods: We performed HR VW-MRI in 4
Stent-Assisted Coiling of Unruptured MCA Aneurysms Using the LVIS Jr. Device: A Multicenter Registry
Autor:
Bartosz Limanówka, Mariusz Banach, Wojciech Poncyljusz, Sławomir Bereza, Leszek Sagan, Miłosz Zbroszczyk, Łukasz Zwarzany
Publikováno v:
Journal of Clinical Medicine, Vol 9, Iss 3168, p 3168 (2020)
Journal of Clinical Medicine
Volume 9
Issue 10
Journal of Clinical Medicine
Volume 9
Issue 10
Purpose: The low-profile visualized intraluminal support junior (LVIS Jr.) is a new generation low-profile braided stent. Our aim was to evaluate the safety and efficacy of the LVIS Jr. in the stent-assisted coiling of unruptured middle cerebral arte
Publikováno v:
European Journal of Radiology. 84:1313-1317
The aim of our study was to evaluate the feasibility of contrast-enhanced flat panel detector CT (FPDCT) for visualizing the novel microstents implanted in patients with unruptured wide-necked intracranial aneurysms.Forty-four cases of patients who u
Publikováno v:
European Journal of Radiology. 84:261-265
Purpose The HydroCoil Embolic System (HES) was developed to improve aneurysm filling to provide superior occlusion efficacy, reduce retreatment rates and enhance long-term durability. We performed a randomized clinical trial to compare the effectiven
Publikováno v:
European journal of radiology. 88
Flat detector CT (FDCT) provides cross sectional imaging within an angiographic suite and is increasingly gaining popularity in various areas of interventional radiology, as an alternative imaging modality. Its relatively high spatial resolution impr