Autor:
Pavlásek Peter, Rybář Jan, Ďuriš Stanislav, Hučko Branislav, Chytil Miroslav, Furdová Alena, Ferková Sylvia Lea, Sekáč Juraj, Suchý Vítězslav, Grosinger Patrik
Publikováno v:
Measurement Science Review, Vol 20, Iss 4, Pp 171-177 (2020)
This paper focuses on the problematic of intraocular pressure (IOP) measurements, performed by non-invasive methods. More specifically, the devices that are connected with the presented finding are non-contact tonometers that use concentrated air str
Externí odkaz:
https://doaj.org/article/bab84995144441d6a82d3a85fe8e6a65
Publikováno v:
Measurement Science Review, Vol 20, Iss 2, Pp 73-79 (2020)
The paper presents a matrix approach to the propagation of uncertainties in the realization of the ITS-90 using Standard Platinum Resistance Thermometers (SPRT) calibrated at Defining Fixed Points (DFPs). The procedure allows correlations to be inclu
Externí odkaz:
https://doaj.org/article/24e65ee1c7a44d92a0b28f50e21e8c3d
Publikováno v:
Measurement Science Review, Vol 19, Iss 5, Pp 209-212 (2019)
Au/Pt thermocouples are considered as an alternative to High Temperature Platinum Resistance Thermometers and are one of the prime candidates to replace them as the interpolating instrument of the International Temperature Scale of 1990 (ITS-90) in t
Externí odkaz:
https://doaj.org/article/94829fb6b0ad48a0918973c5159c427a
Publikováno v:
Measurement Science Review, Vol 19, Iss 1, Pp 9-13 (2019)
The present work focuses on the solution of management of measuring spatial characteristics of security detectors using a positioner, a precision manipulator. It deals with program management software in LabView. Graphical programming with subroutine
Externí odkaz:
https://doaj.org/article/8f44a14a52e84aaa9f95fae54476fca0
Autor:
Palenčár Rudolf, Sopkuliak Peter, Palenčár Jakub, Ďuriš Stanislav, Suroviak Emil, Halaj Martin
Publikováno v:
Measurement Science Review, Vol 17, Iss 3, Pp 108-116 (2017)
Evaluation of uncertainties of the temperature measurement by standard platinum resistance thermometer calibrated at the defining fixed points according to ITS-90 is a problem that can be solved in different ways. The paper presents a procedure based
Externí odkaz:
https://doaj.org/article/dbabaea2677f43febf0b3479fcef9684
Autor:
Zarghoon, Sohaibullah, Emebu, Samuel, Matušů, Radek, Belavý, Cyril, Bartalský, Lukáš, Ďuriš, Stanislav, Husnain, Sabir, Mendoza Martinez, Clara
Publikováno v:
In Engineering Science and Technology, an International Journal July 2024 55
Publikováno v:
In Procedia Engineering 2014 69:1336-1344
Autor:
Chytil Miroslav, Furdová Alena, Pavlásek Peter, Veselý Pavol, Ďuriš Stanislav, Rybář Jan, Hučko Branislav
Publikováno v:
Journal of Mechanical Engineering, Vol 70, Iss 2, Pp 133-140 (2020)
The objective measurement of intraocular pressure (IOP) represents the identification of the symptoms of some diseases, e.g. glaucoma. This objective measurement can only be achieved by correct calibration of tonometers. Today, there is no uniform me
Akademický článek
Tento výsledek nelze pro nepřihlášené uživatele zobrazit.
K zobrazení výsledku je třeba se přihlásit.
K zobrazení výsledku je třeba se přihlásit.
Publikováno v:
Journal of Mechanical Engineering, Vol 69, Iss 2, Pp 111-116 (2019)
The paper deals with the influence of various biomechanical parameters on the intraocular pressure (IOP). The IOP is a very important factor in more accurate diagnosis and better management of glaucoma. To get a more realistic value of IOP the measur