Zobrazeno 1 - 10
of 12
pro vyhledávání: '"Ümit İşkan"'
Publikováno v:
Hittite Journal of Science and Engineering, Vol 11, Iss 2, Pp 49-56 (2024)
In this research, an experimental investigation was conducted on a dual-evaporator ejector system (DEES). The experiments were conducted under two distinct configurations, known as condenser outlet split (COS) and diffuser outlet split (DOS), across
Externí odkaz:
https://doaj.org/article/a4303a3709934f0eb00a5d6f315649ce
Publikováno v:
Hittite Journal of Science and Engineering, Vol 10, Iss 1, Pp 69-76 (2023)
This study aims experimentally to investigate the performance parameters of R134a and the alternative R516A refrigerant in two evaporator ejector cooling system (DEES) at different air velocities of evaporator#1. Firstly, the tests were carried out w
Externí odkaz:
https://doaj.org/article/8e853c81016f4743bb39b71a8020cd81
Publikováno v:
Science and Technology for the Built Environment. :1-10
Publikováno v:
Journal of Innovative Engineering and Natural Science. 1:53-66
Publikováno v:
Energy Sources, Part A: Recovery, Utilization, and Environmental Effects. 44:7316-7329
Publikováno v:
Hittite Journal of Science and Engineering.
This study aims experimentally to investigate the performance analysis of R134a and alternative R516A refrigerant in two evaporator ejector cooling system (DEES) at different air velocities of evaporator#1. Firstly, the tests were carried out with R1
Autor:
Ümit Işkan, Mehmet Direk
Publikováno v:
Energy Sources, Part A: Recovery, Utilization, and Environmental Effects. :1-15
The purpose of this study was to experimentally investigate a dual evaporator ejector system (DEES) operating with R134a and R456a. In order to see the effect of expansion valves in the system, the...
Publikováno v:
International Journal of Pure and Applied Sciences. 7:41-50
Bu çalışmada otomobil klima sisteminde farklı soğutucu akışkanlar kullanılarak kompresör volumetrik verim değerlerinin analizi yapılmıştır. Literatürde önerilen ampirik bağıntıdan elde edilen volumetrik verim değerlerinin çalış
Publikováno v:
Volume: 11, Issue: 1 500-511
Journal of the Institute of Science and Technology
Journal of the Institute of Science and Technology
In this study, the performance of different refrigerants (with low GWP value) depending on thermophysical properties in the cooling system was evaluated. The cooling capacities of R134a, R445a, R515a, R456a, ND, and R516a refrigerants used in the coo
Autor:
Ümit İşkan, Mehmet Direk
Publikováno v:
Thermal Science and Engineering Progress. 33:101345