Zobrazeno 1 - 10
of 13
pro vyhledávání: '"Shantanu Sinha"'
Publikováno v:
Catheterization and Cardiovascular Interventions. 87:75-81
Objectives To evaluate the use of the Boomerang™ Wire as an adjunct to manual compression (MC) in patients requiring diagnostic (Dx) or interventional (Ix) percutaneous procedures. Background MC remains the standard of care for closure of femoral a
Publikováno v:
Experimental Physiology. 96:938-948
The present study examined spatial changes in the muscle activation pattern with different contraction intensity using magnetic resonance imaging (MRI). Transverse relaxation time (T2)-weighted MRI was used to acquire 22 axial slices, which covered t
Publikováno v:
Scopus-Elsevier
In this paper, we evaluate a recently proposed dual-phase dark-blood MR sequence for estimating the left ventricular ejection fraction, compare Simpson's method of estimation of ejection fraction with a model based on the biplane method, assess the r
Autor:
Anthony Rizzo, Rajesh Dave, Gary S. Roubin, Shantanu Sinha, Robert M. Bersin, Barry S. Weinstock, Ravish Sachar, Gary M. Ansel, Robert L. Feldman, H. Bob Smouse
Publikováno v:
Catheterization and cardiovascular interventions : official journal of the Society for Cardiac AngiographyInterventions. 82(2)
Objectives To evaluate the 9-month safety and effectiveness outcomes of the Formula™ balloon-expandable renal stent (Cook Medical, Bloomington, IN) for the treatment of atherosclerotic renal artery stenosis (RAS) following suboptimal angioplasty. B
Publikováno v:
Investigative Radiology. 27:856-864
RATIONALE AND OBJECTIVES To synthesize magnetic resonance images (MRI) in real-time using a minimal data set obtained with routine clinical protocols and stored in a picture archiving and communication system (PACS) database. METHODS Analytic solutio
Publikováno v:
American Journal of Roentgenology. 159:199-205
This article describes an interactive teaching module, linked to a picture archiving and communications system (PACS) data base, for teaching radiology. The module is currently tailored to MR images but can be adapted to any other imaging technique.
Autor:
Shunsuke Natori, Antoinette S. Gomes, Shantanu Sinha, W. Gregory Hundley, Gregory D.N. Pearson, Michael Jerosch-Herold, Andrew E. Arai, J. Paul Finn, David A. Bluemke, Joao A.C. Lima, Shenghan Lai
Publikováno v:
AJR. American journal of roentgenology. 186(6 Suppl 2)
MRI provides accurate and high-resolution measurements of cardiac anatomy and function. The purpose of this study was to describe the imaging protocol and normal values of left ventricular (LV) function and mass in the Multi-Ethnic Study of Atheroscl
Publikováno v:
AJR. American journal of roentgenology. 186(2)
OBJECTIVE. The objective of this study was to describe postprocessing tools for MR phase-contrast flow quantification images and apply those tools to cerebral arteriovenous malformations (AVMs) to visualize blood flow dynamics noninvasively.CONCLUSIO
Publikováno v:
American Journal of Roentgenology. 167:187-189
Publikováno v:
AJR. American journal of roentgenology. 168(3)
OBJECTIVE: MR imaging, with its coronal imaging capability, may be ideally suited for biopsies of hepatic dome lesions. We are reporting on the successful semi-real-time biopsy of such lesions using a 0.2-T open-configuration MR scanner in five patie