Publikováno v:
Lab on a chip. 15(19)
Polystyrene microparticles are trapped on a waveguide Young interferometer and the phase change caused by the trapped particles is measured. This is a novel, on-chip method that can be used to count and characterize trapped particles. The trapping of
Squeezing red blood cells on an optical waveguide to monitor cell deformability during blood storage
Autor:
James S. Wilkinson, Ana Oteiza, Thomas R Huser, Balpreet Singh Ahluwalia, Olav Gaute Hellesø, Peter McCourt
Red blood cells squeeze through micro-capillaries as part of blood circulation in the body. The deformability of red blood cells is thus critical for blood circulation. In this work, we report a method to optically squeeze red blood cells using the e
Externí odkaz:
https://explore.openaire.eu/search/publication?articleId=doi_dedup___::76135d0a4ca71ab1e3d69449e87a5a24
https://eprints.soton.ac.uk/376916/
https://eprints.soton.ac.uk/376916/
Autor:
Olav Gaute Hellesø, Pål Løvhaugen, James S. Wilkinson, Ananth Subramanian, Balpreet Singh Ahluwalia
Publikováno v:
Lab on a chip. 12(18)
Waveguide trapping has emerged as a useful technique for parallel and planar transport of particles and biological cells and can be integrated with lab-on-a-chip applications. However, particles trapped on waveguides are continuously propelled forwar