Zobrazeno 1 - 10
of 22
pro vyhledávání: ''
Autor:
Gerardo T. Martinez, Colum M. O'Leary, Emanuela Liberti, M. J. Humphry, Angus I. Kirkland, Peter D. Nellist
Electron ptychography is a 4-D STEM phase-contrast imaging technique with applications to light-element and beam-sensitive materials. Although the electron dose (electrons incident per unit area on the sample) is the primary figure of merit for imagi
Externí odkaz:
https://explore.openaire.eu/search/publication?articleId=doi_dedup___::a57af40214a4e3d713be6f947bea4f86
https://doi.org/10.1016/j.ultramic.2020.113189
https://doi.org/10.1016/j.ultramic.2020.113189
Autor:
Arai, Yasuo, Furenlid, Lars R., Takeda, Shin’ichiro, Katsuragawa, Miho, Orita, Tadashi, Moriyama, Fumiki, Sugawara, Hirotaka, Oshita, Sayuri, Yabu, Goro, Watanabe, Shin, Takahashi, Tadayuki
Publikováno v:
Nuclear Instruments & Methods in Physics Research. Section A, Accelerators, Spectrometers, Detectors and Associated Equipment. 912:57-60
著者人数: 11名
Accepted: 2017-10-13
資料番号: SA1170374000
Accepted: 2017-10-13
資料番号: SA1170374000
Autor:
S. Bharthuar, Matti Kalliokoski, Esa Tuovinen, Aneliya Karadzhinova-Ferrer, A. Gädda, Panja-Riina Luukka, Laura Martikainen, M. Golovleva, S. Kirschenmann, M. Bezak, Jennifer Ott, V. Litichevsky, V. Chmill, Jaakko Härkönen, Erik Brücken, Alexander Winkler
Publikováno v:
Nuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment
We report initial characterization of our novel sensor process solutions with AC-coupled n + /p − /p + pixel detectors made on 150 mm diameter p-type Magnetic Czochralski silicon (MCz-Si) wafers. The pixels were segmented in a 52 × 80 dual column
Externí odkaz:
https://explore.openaire.eu/search/publication?articleId=doi_dedup___::5768cec92ca1dc54dd0250a2d6555d50
https://aaltodoc.aalto.fi/handle/123456789/47042
https://aaltodoc.aalto.fi/handle/123456789/47042
Autor:
C. I. D. Underwood, C. D. Baird, C. Thornton, Nelson Lopes, Dan Symes, M. J. V. Streeter, Zulfikar Najmudin, J.-N. Gruse, Oliver J. Finlay, David Neely, Y. Katzir, C. D. Murphy, Mark A. Williams, Stuart Mangles, Chris Armstrong, P. P. Rajeev, Kevin D Potter, Dean Rusby, Silvia Cipiccia, Laura Rhian Pickard, Jason M. Warnett, Nicolas Bourgeois, Ceri Brenner, J. C. Wood, Christopher D. Gregory
X-rays generated by betatron oscillations of electrons in a laser-driven plasma accelerator were characterised and applied to imaging industrial samples. With a 125 TW laser, a low divergence beam with 5.2 ± 1.7 × 107 photons mrad−2 per pulse was
Externí odkaz:
https://explore.openaire.eu/search/publication?articleId=doi_dedup___::b5912ee224464121d0af754801ab2ca6
http://hdl.handle.net/10044/1/84084
http://hdl.handle.net/10044/1/84084
Autor:
Harry van der Graaf, Behrouz Raftari, Serge Duarte Pinto, Neil V. Budko, Hassan Akhtar, Kees Vuik, Cornelis W. Hagen, V. Prodanovic, H.W. Chan, John Sinsheimer, Conny Hansson, Shuxia Tao, Gert Nützel, Pasqualina M. Sarro, John Smedley, Anne M.M.G. Theulings
Publikováno v:
Nuclear Instruments and Methods in Physics Research. Section A: Accelerators, Spectrometers, Detectors and Associated Equipment, 847, 148-161. Elsevier
By placing, in vacuum, a stack of transmission dynodes (tynodes) on top of a CMOS pixel chip, a single free electron detector could be made with outstanding performance in terms of spatial and time resolution. The essential object is the tynode: an u
Publikováno v:
Repositorio Institucional de la Universidad de Burgos (RIUBU)
instname
instname
In this work, the transfer of the excitation-emission matrices between a portable fluorimeter based on LEDs and a master fluorimeter based on a xenon source was carried out. Enrofloxacin was the analyte of interest and it was measured alone or in bin
Externí odkaz:
https://explore.openaire.eu/search/publication?articleId=doi_dedup___::44dd58df5712a22402a4e0e52e5674f3
http://hdl.handle.net/10259/5058
http://hdl.handle.net/10259/5058
Autor:
Mauro Casalboni, Sigurd Schrader, E. Santovetti, Davide Badoni, Roberto Ammendola, A. Satta, A. Salamon, G. Paoluzzi, Paolo Prosposito, Fausto Sargeni, Vincenzo Bonaiuto, Andreas Mai, A. Andreazza, Patrick Steglich, Gianluca Alimonti, G. Salina, F. De Matteis
Optical wavelength multiplexing is a widely used technique in Information and Communication Technology to increase maximum data transmission bandwidth on a single optical fiber . We propose wavelength multiplexing/demultiplexing using optical Ring Re
Externí odkaz:
https://explore.openaire.eu/search/publication?articleId=doi_dedup___::cbde95c0bd23c6515160eb65cef89b89
http://hdl.handle.net/2108/205696
http://hdl.handle.net/2108/205696
A Commercial-Off-The-Shelf (COTS) 4H-SiC p-n photodiode (sold as a UV detector) was investigated as detector of electrons (β- particles) over the temperature range 100 °C to 20 °C. The photodiode had an active area of 0.06 mm2. The currents of the
Externí odkaz:
https://explore.openaire.eu/search/publication?articleId=doi_dedup___::8b74f4c69c53abf488d200ac9103d32b
In this paper for the first time, an InGaP photodiode was used in a high temperature tolerant X-ray spectrometer. The use of InGaP in X-ray spectrometers shows a significant advance within this field allowing operation up to 100 °C. Such results are
Externí odkaz:
https://explore.openaire.eu/search/publication?articleId=doi_dedup___::b0a76b70d30e588d212439b9bce3716c
Autor:
Zheng Li, Teppo Mäenpää, Jaakko Härkönen, X. Wu, Alexandra Junkes, E. Tuovinen, T. Arsenovich, A. Gädda, Panja-Riina Luukka, Eija Tuominen
Publikováno v:
Härkönen, J, Tuovinen, E, Luukka, P, Gädda, A, Mäenpää, T, Tuominen, E, Arsenovich, T, Junkes, A, Wu, X & Li, Z 2016, ' Processing of n+/p-/p+ strip detectors with atomic layer deposition (ALD) grown Al2O3 field insulator on magnetic Czochralski silicon (MCz-si) substrates ', Nuclear Instruments and Methods in Physics Research. Section A: Accelerators, Spectrometers, Detectors and Associated Equipment, vol. 828, pp. 46-51 . https://doi.org/10.1016/j.nima.2016.04.069
Detectors manufactured on p-type silicon material are known to have significant advantages in very harsh radiation environment over n-type detectors, traditionally used in High Energy Physics experiments for particle tracking. In p-type (n + segmenta